FLIR T1K infrared cameras are designed for thermography experts who need the highest quality without compromise. With full HD resolution, outstanding thermal sensitivity, and FLIR-exclusive optics designed specifically for HDIR detectors, the T1K raises the bar on performance.
• 1024 x 768 thermal resolution (786,432 detection points)
• Thermal sensitivity 0.02˚C@30 ˚C
• 8X Continuous Zoom
• High temperature option to +2000°C
• Full range of wide-angle, tele and close-up lens
• Text, sketch, and draw-direct annotation
• Video recording and periodic save function
• Customized measurement presets
• UltraMax™ resolution enhancement to 2048 x 1536
| Thermal Camera | |
| Focal Plane Array (FPA) / Spectral range | Uncooled microbolometer / 7.5-14 μm |
| IR resolution | 1024 x 768 pixels |
| Thermal sensitivity / NETD | <0.02°C @ +30°C (+86°F) / 20mK |
| Field of view (FOV) / Minimum focus distance | 28° x 21° / 0.4m (1.31 ft.) |
| Spatial resolution (IFOV) | 0.47 mrad |
| Focus | Automatic or Manual |
| Zoom | 1 - 8x continuous, digital zoom |
| Object temperature range |
-40°C to +150°C (-40°F to +302°F), +0°C to +650°C (+32°F to +1202°F) +300°C to +2000°C (+572°F to +3632°F) (optional upgrade) |
| Accuracy | ±2°C (±3.6°F) or ±2% of reading |
| Spotmeter | 10 |
| Area | 5 boxes with max / min / average |
| Automatic hot / cold detection | Auto hot or cold spotmeter markers within area |
| Isotherm | Above / below / interval |
| Emissivity correction | Variable from 0.01 to 1.00 or selected from materials list |
| Measurement corrections | Reflected temperature, optics transmission and atmospheric transmission |